record THERMCORD3 – Thermally Insulated Doors
Drive Dimensions
|
|
Doppelschiebetüre |
Einblattschiebetüre |
Without side piece (depth x height) |
157 x 150 mm / 167 x 200 mm |
157 x 150 mm / 167 x 200 mm |
With side piece (depth x height) |
210 x 150 mm / 200 mm |
210 x 150 mm / 200 mm |
General technical specifications
|
Width of passage A |
800 – 3 000 mm |
800 – 2 500 mm |
Height of passage G |
max. 3 000 mm |
max. 3 000 mm |
Support beam length F |
min. 2 A + 250 mm |
min. 2 A + 125 mm |
Total height J |
G + 150 mm bzw. 200 mm |
G + 150 mm bzw. 200 mm |
Door leaf weight |
(record STA 20) 2 x 120 kg |
(record STA 20) 1 x 150 kg |
Door leaf weight DUO/RED |
(record STA 20) 2 x 150 kg |
(record STA 20) 1 x 150 kg |
Power supply voltage |
100 – 240 V AC, 50 / 60 Hz |
100 – 240 V AC, 50 / 60 Hz |
Rated power |
90 W |
90 W |
Consumption in standby mode |
ca. 25 W |
ca. 25 W |
Operating conditions
|
Ambient temperature |
− 15° bis + 50° C |
− 15° bis + 50° C |
Humidity range |
bis 85 % rel. Feuchte, nicht kondensierend |
bis 85 % rel. Feuchte, nicht kondensierend |
Functional safety
|
Standard compliance |
EN 16 005, DIN 18 650, EN 16 361 |
EN 16 005, DIN 18 650, EN 16 361 |